5. Loosen and remove the two screws (4) from bracket (5).
6. Insert the left side of cutter bracket (7) and secure the two screws (6) to
the TPH module.
7. Thread the cutter cable through hole (8) and route it to the JP16 connector
(CUTTER) on the FM 4602 PLUS series main boards, or to the JP14
connector (CUTTER) on the main board of FM 4603 PLUS series.
8. Turn on the printer.
9. Set parameter “CUTTER INSTALLED”, on the LCD to the ON position.