Diagnostic Test Functions
Hexadecimal Dump Function
The hexadecimal dump function produces an exact printout of the codes received by
the printer.
Procedure:
1. To enter the hexadecimal dump mode, depress the SPEED button while turning
ON the printer's power.
2. When the host sends output to the printer, all codes and data are printed in
hexadecimal format. The example as below.
NOTE: Load the paper along the left side (the 0 mark on the ruler).
3. By comparing the characters printed in the right column with the hex codes, you
can verify exactly what codes are being sent to the printer. If the code sent is a
printable character (20h-7Eh), that character is printed in the right column. If the
code sent is a non-printable character, such as a control code, a dot is printed.
4. To exit from the hexadecimal dump mode, turn off the power switch or press the
RESET ([ALT] + [SPEED]) button.
END OF PROCEDURE
Self-Test Function
The self-test prints a continuous pattern of ASCII characters. The font and print quality
is determined by the control panel or menu settings.
Procedure:
1. To initiate the self-test, depress the LF button while turning ON the printer’s
power.
2. To terminate or stop the self-test function, either turn off the power or press the
RESET ([ALT] + [SPEED]) button.
END OF PROCEDURE
***** HEXADECIMAL DUMP *****
(0000) 1B 40 A9 A6 29 29 A9 A6 2A 2A A9 A6 2B 2B A9 A6
(0010) 2C 2C A9 A6 2D 2D A9 A6 2E 2E A9 A6 2F 2F A9 A6
(0020) 30 30 A9 A6 31 31 A9 A6 32 32 A9 A6 33 33 A9 A6
(0030) 34 34 A9 A6 35 35 A9 A6 36 36 A9 A6 37 37 A9 A6