Configuring Data Sources
The LLM Script data source provides a means for applying the ISBT 128 standard to your barcode
labels. For example, you can enter a script to compute the checksum character based on the mod 37-2
algorithm. Appendix D of the ICCBBA technical specification document describes the steps in this
process and includes a sample C language function that can guide you in creating a JavaScript for the
Script data source.
In the sample ISBT 128 label below, barcodes 1 to 4 are required. These and their recommended
positioning on the label are also described in the ICCBBA technical specifications document.
Figure 8.6: Sample ISBT Label
Database Data Source
Using databases can greatly simplify the printing process and eliminate the chances of data entry error.
In a typical application, the user enters a key piece of information (for example a part number) and
Loftware Label Manager retrieves other data for the label based on the key.
For every database table that is connected to a label, one field (and only one) must be identified as the
key field. This means that the key field is used to look up data information from the database.
The Database Data Sources and ODBC
Loftware Label Manager features 32-bit ODBC (Open Database Connectivity) functionality. This allows
Loftware Label Manager to retrieve information from database applications supporting the ODBC
standards.